A spotlight near a sink can face splashes that a fitting in a dry corridor never sees. Start by listing what will reach the fitting in that location, such as airborne dust, splashes or water used during cleaning. Then read the IP code and installation notes for the exact luminaire you intend to use.
The original Rayvon catalogue photo shows recessed frame 1622. The catalogue leaves its IP rating unspecified. IP44 and IP65 below are examples of the code. Check the rating in the documentation for the complete installed luminaire.
The two digits in an IP code
IEC 60529 classifies the protection provided by an enclosure. The first digit covers access to hazardous parts and the entry of solid foreign objects. The second covers the entry of water and its effects under specified test conditions. Both digits matter when you compare two fittings for a location exposed to dust and water.
For example, IP44 covers solid objects of 1 mm and larger and splashing water under the applicable tests. IP65 denotes a dust-tight enclosure and protection against water jets under its test conditions. Water exposure takes different forms. Use the code and the applicable installation guidance for the particular exposure.
The complete fitting and its location
Check which assembly the rating applies to. With a recessed fitting, the visible face below the ceiling and the part above the ceiling may have different documented protection. For a track system, check the components exposed at the mounting position. The installation instructions explain the conditions the fitting must meet, including any specified seals or mounting orientation.
If the same fitting appears over a sink and in a corridor on the drawings, record the conditions at both locations. Review each position with the person responsible for the electrical installation before ordering.
Protection checklist
- Record the exposure at each proposed location.
- Find the rating for the exact fitting and its installed configuration.
- Check the position and any installation conditions with the person responsible for the electrical work.
When choosing Magnetic lighting modules or Spotlight frames, ask for the documentation that covers the assembled light. Use the frame reference to identify the part, then match the complete fitting to the location.
Sources
- IEC 60529 – Degrees of Protection Provided by Enclosures
- iGuzzini – Laser Blade L Recessed Luminaire Protection
- ERCO – Outdoor Lighting and IP65 Protection